        i.            Measurement on cross sectional area of wires.
This analysis is to determine and compare the two different types of AWG wires. One is 23 AWG and the other is 20 AWG.
No
Description
Value for 20 AWG
Value for 23 AWG
1
Area cross section
1.020 mm2
0.259 mm2
2
Wire diameter
0.081 cm
0.057 cm
3
Permeability of coil
              4π x 10-7
              4π x 10-7
4
Radius of wire
0.040 cm
0.029 cm
5
Max current
1.5A
0.729A
6
Max frequency
27 kHz
53 kHz

Comparison of 20 AWG and 23 AWG


a) The result below shows the comparison between using the fixed diameter of turns and number of turns.
When Transmitter size=18N,10cm and
 Receiver diameter of turns is fixed, d =9cm

Transmitter
Receiver
Maximum distance for
23 AWG
(cm)
Maximum distance for
20AWG
(cm)
No. of turns
Diameter of turns
No. of turns
Diameter of turns
18N
10cm
7N
9cm
2cm
3.5cm
10N
9cm
5cm
5.5cm
12N
9cm
6cm
7cm
14N
9cm
7cm
9cm
Result on distance based on different AWG

Graph on distance based on different AWG


b)The condition when measurement at 2cm distance.
When Transmitter size=18N,10cm and
 Receiver diameter of turns is fixed, d =9cm
Transmitter
Receiver
Output voltage for
23 AWG
Output voltage for
20 AWG
No. of turns
Diameter of turns
No. of turns
Diameter of turns
18N
10cm
7N
9cm
1.87V
2.89V
10N
9cm
3.92V
5.46V
12N
9cm
6.07V
8.18V
14N
9cm
7.31V
10.11V

Result on output voltage based on different AWG

Graph on output voltage based on different AWG