        i.            Measurement on distance
The result below shows the comparison between using the fixed diameter of turns and number of turns.

a)When Transmitter size=18N,10cm and

    Receiver diameter of turns is fixed, d =9cm

Transmitter
Receiver
Maximum distance
(cm)
No. of turns
Diameter of turns
No. of turns
Diameter of turns
18N
10cm
10N
9cm
5cm
12N
9cm
6cm
14N
9cm
7cm
20N
9cm
15cm



From the Graph on Distance 1, observation is made to achieve the maximum distance. The  transmitter size is 18N,10cm. The diameter of turns at receiver is fixed for 9cm.The maximum distance stated when the receiver at the size 20N,9cm which is 15cm. The lowest value stated when the receiver at the size 10N,9cm which is 5cm. The graph shows gradually increased because the transmitter size is bigger than the receiver size.



     